Generator Columns and High Pressure Liquid Chromatography for Determining Aqueous Solubilities and Octanol-Water Partition Coefficients of Hydrophobic Substances

利用生成柱和高效液相色谱法测定疏水性物质的水溶性和辛醇-水分配系数

阅读:2

Abstract

Generator columns packed with a solid support and loaded with a liquid organic phase make it possible to rapidly and conveniently equilibrate water with the organic phase. By coupling the generator column to an extractor column for high pressure liquid chromatographic analysis of the aqueous solution, errors from surface adsorption and loss to the atmosphere are avoided. Using this method, the mean values and confidence limits at a 95 percent confidence level of the aqueous solubility, S, and the octanol-water partition coefficient, P, of n-propylbenzene at 25 °C were found to be S = (4.32 ± 0.02) × 10(-4) M and log P = 3.720 ± 0.003.