Study on the optical property and biocompatibility of a tissue engineering cornea

组织工程角膜的光学特性及生物相容性研究

阅读:8
作者:Xu Zhang, Yukiko Nakahara, Dwight Xuan, Di Wu, Fang-Kun Zhao, Xiao-Yan Li, Jin-Song Zhang

Aim

To study the optical property and biocompatibility of a tissue engineering cornea.

Conclusion

Collagen scaffold can be molded to the shape of soft contact corneal lens with NHS/EDC. The biological stability and biocompatibility of collagen from animal species may be used as material in preparing to engineer artificial corneal scaffold.

Methods

: The cross-linker of N-(3-Dimethylaminoropyl)-N'ethylcarbodiimide hydrochloride (EDC)/N-Hydroxysuccinimide (NHS) was mixed with Type I collagen at 10% (weight/volume). The final solution was molded to the shape of a corneal contact lens. The collagen concentrations of 10%, 12.5%, 15%, 17.5% and 20% artificial corneas were tested by UV/vis-spectroscopy for their transparency compared with normal rat cornea. 10-0 sutures were knotted on the edges of substitute to measure the corneal buttons's mechanical properties. Normal rat corneal tissue primary culture on the collagen scaffold was observed in 4 weeks. Histopathologic examinations were performed after 4 weeks of in vitro culturing.

Results

The collagen scaffold appearance was similar to that of soft contact lens. With the increase of collagen concentration, the transparency of artificial corneal buttons was diminished, but the toughness of the scaffold was enhanced. The scaffold transparency in the 10% concentration collagen group resembled normal rat cornea. To knot and embed the scaffold under the microscope, 20% concentration collagen group was more effective during implantation than lower concentrations of collagen group. In the first 3 weeks, corneal cell proliferation was highly active. The shapes of cells that grew on the substitute had no significant difference when compared with the cells before they were moved to the scaffold. However, on the fortieth day, most cells detached from the scaffold and died. Histopathologic examination of the primary culture scaffold revealed well grown corneal cells tightly attached to the scaffold in the former culturing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。