Effect of Compression, Digital Noise Reduction and Directionality on Envelope Difference Index, Log-Likelihood Ratio and Perceived Quality

压缩、数字降噪和方向性对包络差分指数、对数似然比和感知质量的影响

阅读:1

Abstract

The aim of the present study was to evaluate the use of the envelope difference index (EDI) and log-likelihood ratio (LLR) to quantify the independent and interactive effects of wide dynamic range compression, digital noise reduction and directionality, and to carry out self-rated quality measures. A recorded sentence embedded in speech spectrum noise at +5 dB signal to noise ratio was presented to a four channel digital hearing aid and the output was recorded with different combinations of algorithms at 30, 45 and 70 dB HL levels of presentation through a 2 cc coupler. EDI and LLR were obtained in comparison with the original signal using MATLAB software. In addition, thirty participants with normal hearing sensitivity rated the output on the loudness and clarity parameters of quality. The results revealed that the temporal changes happening at the output is independent of the number of algorithms activated together in a hearing aid. However, at a higher level of presentation, temporal cues are better preserved if all of these algorithms are deactivated. The spectral components speech tend to get affected by the presentation level. The results also indicate the importance of quality rating as this helps in considering whether the spectral and/or temporal deviations created in the hearing aid are desirable or not.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。