Ultrasound-guided percutaneous peritoneal dialysis catheter insertion using multifunctional bladder paracentesis trocar: A modified percutaneous PD catheter placement technique

超声引导下经皮腹膜透析导管置入术:一种改良的经皮腹膜透析导管置入技术

阅读:1

Abstract

BACKGROUND: To evaluate the efficacy and safety of ultrasound-guided percutaneous peritoneal dialysis catheter insertion using multifunctional bladder paracentesis trocar. METHODS: A retrospective review of 103 ESRD patients receiving percutaneous PD catheter insertion using a multifunctional bladder paracentesis trocar under ultrasound guidance at a single center between May 2016 and May 2018. Mechanical complications and catheter survival were evaluated over a 12-month follow-up. RESULT: Catheterization using this technique required only 10-30 minutes from the beginning of local anesthesia to the end of skin suture at the puncture site (mean 18 ± 7 minutes) and an incision length of 2-4 cm. Moreover, only four of 103 cases required catheter removal due to poor drainage within one month after surgery, with a success rate of 96.19%. Among failures, omentum wrapping was cause in two cases, catheter displacement in one case, and protein clot blockage in one case, while there were no instances of organ injury, severe hemorrhage, peritubular leakage, hernia, peritonitis, or exit infection within one month of PD catheter insertion. Catheter survival at 1 year was 92.2%. CONCLUSION: Percutaneous PD catheter insertion using a multifunctional bladder paracentesis trocar and ultrasound guidance is a feasible technique for ESRD patients.