Hydrogel coated mesh decreases tissue reaction resulting from polypropylene mesh implant: implication in hernia repair

水凝胶涂层网片可减少聚丙烯网片植入物引起的组织反应:对疝修补的意义

阅读:9
作者:D P Poppas, J J Sung, C M Magro, J Chen, J P Toyohara, B J Ramshaw, D Felsen

Conclusion

These results demonstrate that a non-biodegradable hydrogel coating of PPM led to significant reduction in foreign body reaction, oxidative stress and apoptosis compared to uncoated PPM in vivo, and suggest that this coating could be clinically useful in hernia repair.

Methods

Through a dorsal midline incision, a 2 cm × 2 cm section of PPM (either coated or uncoated) was placed on the fascial surface 1.5 cm from the incision on the dorsal wall of Sprague-Dawley rats. At 2 and 12 weeks after placement, the PPM and surrounding tissue were harvested. A board-certified dermatopathologist examined H&E stained slides for fibrosis and foreign body reaction. In addition, tissues were stained for apoptotic cells, oxidative damage, macrophages, fibroblasts, neovascularization and metalloproteases.

Purpose

Use of polypropylene mesh (PPM) in hernia repair is associated with tissue reactivity. We examined, in a rat model, a novel non-biodegradable hydrogel coated PPM which may allow for decreased inflammation and a decreased foreign body reaction.

Results

At 2 and 12 weeks, there was a greater than 95 % decrease in foreign body giant cells in coated PPM samples compared to uncoated; fibrosis was decreased by 50 %. At 2 and 12 weeks, oxidative damage, fibroblast accumulation, apoptosis and macrophages were significantly decreased in coated PPM samples compared to uncoated PPM.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。