Reliability and Validity of Radiographic Measurement of the Humerus-Elbow-Wrist Angle in Healthy Children

健康儿童肱骨-肘-腕角放射影像测量的信度和效度

阅读:1

Abstract

This article was updated on May 4, 2017, because of a previous error. The proximal line drawn in Figure 1 was different from the line described in the Materials and Methods section, which reads "The proximal line was drawn at the level of the radial tuberosity, and the distal line was made at the level of the top of the radial bowing (Fig. 1)." The correct figure is presented in this version of the article. An erratum has been published: JBJS Open Access. 2017 May 26;2(2):e0012ER. BACKGROUND: We conducted a retrospective cohort study to evaluate the normal value, range, reliability, and validity of measurement of the humerus-elbow-wrist angle, an index of valgus-varus angulation of the elbow, in healthy children. This measurement has been used to assess postoperative radiographic results. METHODS: Radiographs of the elbow in 62 healthy children ranging from 2 to 11 years of age were reviewed by 6 examiners at 2 sessions. The mean value and the reliability of measurement of the humerus-elbow-wrist angle, the carrying angle, and the Baumann angle were assessed. Intraobserver and interobserver reliability were calculated with use of intraclass correlation coefficients (ICCs). To determine concurrent validity, the association between the humerus-elbow-wrist angle and carrying angle measurements was examined with use of Pearson correlation coefficients. RESULTS: The mean humerus-elbow-wrist angle value was 12.0° (range, 1° to 24°), and the mean carrying angle was 14.6° (range, 4° to 28°). The ICCs for intraobserver measurements of the humerus-elbow-wrist angle were almost perfect for 4 examiners and were substantial for 2 examiners, with a mean value of 0.85 (range, 0.73 to 0.94). The ICCs for interobserver reliability with regard to the first and second measurements of the humerus-elbow-wrist angle were both substantial (0.76 and 0.78). A significant association between the humerus-elbow-wrist angle and the carrying angle was observed, with the Pearson correlation coefficients ranging from 0.74 to 0.90 (p < 0.001). CONCLUSIONS: Measurement of the humerus-elbow-wrist angle demonstrated good reliability and validity. The humerus-elbow-wrist angle is a reliable radiographic measure of coronal alignment of the humerus and forearm.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。