Comparison between 22G aspiration and 22G biopsy needles for EUS-guided sampling of pancreatic lesions: A meta-analysis

22G穿刺针与22G活检针在超声内镜引导下胰腺病变取样中的比较:一项荟萃分析

阅读:1

Abstract

BACKGROUND AND OBJECTIVE: Robust data in favor of clear superiority of 22G fine-needle biopsy (FNB) over 22G FNA for an echoendoscopic-guided sampling of pancreatic masses are lacking. The objective of this study is to compare the diagnostic outcomes and sample adequacy of these two needles. MATERIALS AND METHODS: Computerized bibliographic search on the main databases was performed and restricted to only randomized controlled trials. Summary estimates were expressed regarding risk ratio (RR) and 95% confidence interval. RESULTS: A total of 11 trials with 833 patients were analyzed. The two needles resulted comparable in terms of diagnostic accuracy (RR 1.02, 0.97-1.08; P = 0.46), sample adequacy (RR 1.01, 0.96-1.06; P = 0.61), and histological core procurement (RR 1.01, 0.89-1.15; P = 0.86). Pooled sensitivity in the diagnosis of pancreatic cancer was 93.1% (87.9%-98.4%) and 90.4% (86.3%-94.5%) with biopsy and aspirate, respectively, whereas specificity for detecting pancreatic cancer was 100% with both needles. Analysis of the number of needle passes showed a nonsignificantly positive trend in favor of FNB (mean difference: -0.32, -0.66-0.02; P = 0.07). CONCLUSION: Our meta-analysis stands for a nonsuperiority of 22G FNB over 22G FNA; hence, no definitive recommendations on the use of a particular device can be made.