Determining the SARS-CoV-2 Anti-Spike Cutoff Level Denoting Neutralizing Activity Using Two Commercial Kits

使用两种商业试剂盒确定SARS-CoV-2抗刺突蛋白中和活性的临界值

阅读:2

Abstract

BACKGROUND: The viral neutralization assay is the gold standard to estimate the level of immunity against SARS-CoV-2. This study analyzes the correlation between the quantitative Anti-SARS-CoV-2 QuantiVac ELISA (IgG) and the NeutraLISA neutralization assay. METHODS: 650 serum samples were tested for both SARS-CoV-2 anti-spike (anti-S) immunoglobulin G (IgG) and neutralizing antibodies (nAbs) using kits by EUROIMMUN, Germany. RESULTS: There was a significant correlation between levels of anti-S and nAbs (Spearman's rho = 0.913). Among the positive samples for anti-S, 77.0% (n = 345) were positive for nAbs. There was a substantial agreement between anti-S and nAbs (Cohen's kappa coefficient = 0.658; agreement of 83.38%). Considering NeutraLISA as a gold standard, anti-S had a sensitivity of 98.57%, specificity of 65.66%, NPV of 97.5%, and PPV of 77.0%. When the anti-S titer was greater than 18.1 RU/mL (57.9 BAU/mL), nAbs were positive, with a sensitivity of 90.0% and specificity of 91%. CONCLUSIONS: A titer of SARS-CoV-2 anti-S IgG can be correlated with levels of nAbs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。