Pulmonary Tuberculosis Detection with MiniDock MTB Using Swab Samples

使用MiniDock MTB通过拭子样本检测肺结核

阅读:2

Abstract

BACKGROUND: Improved diagnostic tools for tuberculosis that are suitable for use in peripheral health centers are essential for reducing the persistent gap between estimated and notified cases. The diagnostic accuracy and usability of the MiniDock MTB test for detecting pulmonary tuberculosis is unknown. METHODS: We conducted a prospective, cross-sectional study at outpatient centers in India, Nigeria, the Philippines, South Africa, Uganda, Vietnam, and Zambia. Patients 12 years of age or older with presumptive pulmonary tuberculosis were enrolled between September 12, 2024, and March 31, 2025. Assessment with MiniDock MTB was performed with sputum swabs and tongue swabs. Diagnostic accuracy was evaluated against a sputum-culture-based reference and as compared with sputum-smear microscopy and Xpert MTB/RIF Ultra assay. Usability was assessed with a system usability scale and direct observation. RESULTS: A total of 1380 participants were enrolled; 255 (18.5%) had human immunodeficiency virus infection and 226 (16.4%) had culture-confirmed tuberculosis. MiniDock MTB sensitivity was 85.7% (95% confidence interval [CI], 80.4 to 90.0) with sputum and 79.6% (95% CI, 73.8 to 84.7) with tongue swabs; specificity was greater than 97.5% for both. Results of sputum tests with MiniDock MTB closely matched those with Xpert MTB/RIF Ultra for sensitivity (difference, -2.8 percentage points; 95% CI, -6.0 to 0.5). MiniDock MTB had greater sensitivity than smear microscopy for tests of sputum (difference, 24.3 percentage points; 95% CI, 17.9 to 30.7) and tongue swabs (difference, 18.3 percentage points; 95% CI, 12.0 to 24.7). The test showed diagnostic accuracy that was consistent with World Health Organization (WHO) accuracy targets for near-point-of-care tuberculosis diagnostics (≥85% sensitivity for sputum and ≥75% for nonsputum and ≥98% specificity for both). The median score on the system usability scale (range, 0 to 100, with higher scores indicating better perceived usability) was 75 (interquartile range, 65 to 80), which indicated good usability. No adverse events related to the index test were reported. CONCLUSIONS: MiniDock MTB met WHO targets for diagnostic accuracy and usability for tuberculosis detection across diverse clinical settings. (Funded by the National Institutes of Health and others; Rapid Research in Diagnostics Development for TB Network and Assessing Diagnostics at Point-of-Care for Tuberculosis ClinicalTrials.gov numbers, NCT04923958 and NCT05941052.).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。