Influence of Accuracy and Precision of Measurements of Long Bone Tumors in Imaging Studies-A Retrospective Study in Musculoskeletal Oncology

影像学研究中长骨肿瘤测量准确性和精确性的影响——一项肌肉骨骼肿瘤学回顾性研究

阅读:1

Abstract

The aim of this study is to evaluate the level of accuracy and precision of bone scan (BS), MRI, and digital radiography (DR) to measure long bone tumors to design custom-made prosthesis (CMP)/modular prosthesis (MP) in limb salvage surgery (LSS) with the help of phantom and patient's study. There are two separate groups: one is the phantom study and another one is the patient's study. The phantom study is done with the Jaszack Phantom for the Gamma camera and the indigenous phantom for the MRI and DR. Three independent imaging professionals (nuclear medicine physicians and radiologists) measured the distance between standardized, preselected points on the Jaszack phantom in the Gamma Camera (GC) and indigenous phantom on the coronal and sagittal view of the MRI scan and in digital radiography. The measured values were compared with the known values for phantom measurement. A total of 36 patients, which include 24 males and 12 females, 3 independent imaging professionals measured the patient's long bone in a bone scan, MRI and DR and compared it with histopathological specimen measurement after limb salvage surgery (LSS). Descriptive statistics using appropriate measures of central tendency and dispersion were employed to describe the data. Karl-Pearson correlation coefficient was used to establish the association between continuous covariates. Paired t-test was utilized to test the differences in paired values for statistical significance. A near-perfect positive correlation was evident between all three pairs of bone scan, MRI scan, and digital radiography values, and a positive agreement within 1 mm of the bone scan, MRI scan, and DR values of all three pairs was around 95%. For the phantom study, we conclude that Gamma camera and MRI measurements are equal in physical measurements (MCF-1). DR measurements were found to be near equal physical measurements and multiplication correction factor (MCF)-0.9104 and three observer's measurements values were also near normal. For the patient's study, we conclude that the bone scan, MRI, and DR measurements of 3 independent imaging professionals are near normal, and it was confirmed with pathological specimen after LSS, to confirm reliability, repeatability, reproducibility, and accuracy of the tumor length to do custom-made prosthesis or modular prosthesis for the patients who are affected by osteosarcoma and Ewing's sarcoma.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。