Contactless vital signs monitoring in macaques using a mm-wave FMCW radar

利用毫米波FMCW雷达对猕猴进行非接触式生命体征监测

阅读:1

Abstract

Heart rate (HR) and respiration rate (RR) play an important role in the study of complex behaviors and their physiological correlations in non-human primates (NHPs). However, collecting HR and RR information is often challenging, involving either invasive implants or tedious behavioral training, and there are currently few established simple and non-invasive techniques for HR and RR measurement in NHPs owing to their stress response or indocility. In this study, we employed a frequency-modulated continuous wave (FMCW) radar to design a novel contactless HR and RR monitoring system. The designed system can estimate HR and RR in real time by placing the FMCW radar on the cage and facing the chest of both awake and anesthetized macaques, the NHP investigated in this study. Experimental results show that the proposed method outperforms existing methods, with averaged absolute errors between the reference monitor and radar estimates of 0.77 beats per minute (bpm) and 1.29 respirations per minute (rpm) for HR and RR, respectively. In summary, we believe that the proposed non-invasive and contactless estimation method could be generalized as a HR and RR monitoring tool for NHPs. Furthermore, after modifying the radar signal-processing algorithms, it also shows promise for applications in other experimental animals for animal welfare, behavioral, neurological, and ethological research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。