Temperature field analysis and compensation improvement of load cell

称重传感器的温度场分析及补偿改进

阅读:1

Abstract

During the operation of load cell, heat is generated by the strain gauge and the electronics on the PCB board, which leads to temperature gradients within the sensor itself. These temperature gradients are unstable at different ambient temperatures. Compensation inaccuracies can also occur when compensating for sensor measurements at different temperatures This paper proposes a method to change the position of temperature compensation resistors to address errors caused by the temperature field effect of the strain gauge sensor itself. Without affecting the sensor's strain measurement, the correctness of the proposed method is demonstrated through steady-state thermal simulation results in ANSYS and experimental results, effectively addressing errors caused by unstable temperature gradients during the operation of strain gauge sensors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。