Iatrogenic descending thoracic aorta perforation by pedicle screws as a delayed complication of scoliosis correction surgery. The anesthetic management and TEE role

医源性降主动脉穿孔(椎弓根螺钉穿孔)是脊柱侧弯矫正手术的迟发并发症。麻醉管理和经食道超声心动图的作用

阅读:1

Abstract

A 29-year-old lady was referred to us with a rare complication of scoliosis correction surgery. She had two of the screws migrated and penetrated the descending thoracic aorta. She came to theater to have the screws removed and the aorta repaired endovascularly. The successful intervention needed a multidisciplinary team planning, coordinated work, and communication between the four involved teams: anesthesia, vascular surgery, interventional radiology, and spine surgery. There was a lot of anesthetic challenges that were new to us because of the rarity of that complication. In addition, it was another situation where the trans-esophageal echocardiography was found very useful and affected the decision making by visualizing the screws inside the aorta. The outcome was successful, and the patient was discharged home safely, hence, we would like to share our experience in managing this difficult case to help others who might find themselves in a similar situation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。