Multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide luminophores and K2S2O8/H2O2 coreactants-based dual amplified electrochemiluminescence immunosensor for ultrasensitive detection of anti-myeloperoxidase antibody

多功能 PtCo 纳米酶/CdS 纳米晶体@氧化石墨烯发光体和基于 K2S2O8/H2O2 共反应物的双放大电化学发光免疫传感器用于超灵敏检测抗髓过氧化物酶抗体

阅读:3
作者:Wei Yang #, Zheng Zhou #, Haiping Wu, Changjin Liu, Bo Shen, Shijia Ding, Yonglie Zhou

Background

Anti-myeloperoxidase antibody (anti-MPO) is an important biomarker for anti-neutrophil cytoplasm antibody (ANCA)-associated vasculitides (AAVs). However, the complicated operation procedures and insufficient sensitivity of conventional anti-MPO detection

Conclusions

The introduction of multi-function PtCo/CdS@GO luminophores into the established ECL immunoassay not only was successfully applied for specific detection of anti-MPO in clinical serum samples, but also provided a completely new concept to design other high-performance luminophores. Meaningfully, the ECL immunoassay strategy held wide potential for biomarkers detection in clinical diagnosis.

Results

PtCo/CdS@GO luminophores as novel signal amplification labels and nanocarriers to load rabbit anti-mouse IgG were synthesized by co-doping with Pt and Co nanozymes simultaneously with several considerable advantages, including astonishing peroxidase-like catalytic activity, high-efficiency luminescence performance and superior stability in aqueous solutions. Meanwhile, upon the K2S2O8/H2O2 coreactants system, benefiting from the efficient peroxidase-like activity of the PtCo/CdS@GO toward H2O2, massive of transient reactive intermediates could react with K2S2O8, thus obtaining higher ECL emission. Therefore, the developed ECL immunosensor for anti-MPO detection displayed good analytical performance with good concentration linearity in the range of 0.02 to 1000 pg/mL and low detection limit down to 7.39 fg/mL. Conclusions: The introduction of multi-function PtCo/CdS@GO luminophores into the established ECL immunoassay not only was successfully applied for specific detection of anti-MPO in clinical serum samples, but also provided a completely new concept to design other high-performance luminophores. Meaningfully, the ECL immunoassay strategy held wide potential for biomarkers detection in clinical diagnosis.