Indoor particulate matter concentrations and air cleaner intervention association with biomarkers in former smokers with COPD

室内颗粒物浓度和空气净化器干预与 COPD 前吸烟者生物标志物的关系

阅读:2
作者:Ashraf Fawzy, Han Woo, Sarath Raju, Daniel C Belz, Nirupama Putcha, Marlene S Williams, Meredith C McCormack, Kirsten Kohler, Nadia N Hansel

Background

Indoor pollutants have been associated with worse clinical outcomes in chronic obstructive pulmonary disease (COPD). Elevated biomarkers are associated with ambient pollution exposure, however the association with indoor pollution remains unclear.

Discussion

Among former smokers with COPD, elevated levels of indoor air pollutants, particularly ultrafine particles (PM<0.1), were associated with elevated biomarkers of inflammation, platelet activation, and oxidative stress. However, an air cleaner intervention that reduced PM did not significantly reduce biomarker levels.

Methods

Former smokers with spirometry-confirmed COPD were randomized to portable air cleaner or placebo. Indoor particulate matter (PM2.5, PM10, and ultrafine particles [UFP; PM<0.1]) and biomarkers were measured longitudinally at pre-specified intervals and course PM fraction (PM10-2.5) was calculated. Biomarkers were categorized based on associations with biologic mechanisms: inflammation (white blood cell count, interleukin [IL]-6, IL-8, IL-1β, tumor necrosis factor-α, interferon-γ, serum amyloid A), platelet activation (P-selectin, CD40 ligand [CD40L], 11-dehdydro-thromboxane-B2 [11dTxB2]), endothelial dysfunction (Vascular Cell Adhesion Molecule [VCAM]-1, Intercellular Adhesion Molecule [ICAM]-1), and oxidative stress (thiobarbituric acid reactive substances [TBARS], 8-hydroxydeoxyguanosine, 8-isoprostane). Associations between PM concentrations and each biomarker were analyzed using multivariable linear mixed models. An intention-to-treat analysis was performed to evaluate the air cleaner intervention on the biomarker levels longitudinally.

Results

Fifty-eight participants were randomized to each group. Finer PM was more strongly associated with higher IL-8 (mean difference per doubling: UFP 13.9% [p = 0.02], PM2.5 6.8% [p = 0.002], PM10-2.5 5.0% [p = 0.02]) while interferon-γ was associated with UFP and IL-1β with PM10-2.5. UFP and PM2.5 were associated with elevated levels of the oxidative stress biomarkers TBARS and 8-isoprostane respectively. For platelet activation markers, UFP was associated with higher 11dTxB2 while PM2.5 was associated with higher P-selectin and CD40L. Pollutants were not associated with biomarkers of endothelial dysfunction. In intention-to-treat analysis there was no association of the air cleaner intervention with any of the biomarkers.