BACKGROUND: Heart diseases, particularly heart failure, significantly impact patient quality of life and mortality rates. Functional capacity assessment is vital for predicting prognosis and risk in these patients. While the cardiopulmonary exercise test is considered the gold standard, the 6-minute walk test has emerged as a more accessible alternative. However, the screening accuracy and optimal cut-off points of the 6-minute walk test for detecting severely reduced functional capacity in cardiac pathologies, including heart failure with preserved ejection fraction, are unclear. The study aimed to analyse the diagnostic accuracy of the 6-minute walk test for detecting reduced functional capacity, defined as VO(2max)â<â14 ml/kg/min, compared with the cardiopulmonary exercise test in participants with heart failure with preserved ejection fraction using data from the "Ejercicio en Insuficiencia Cardiaca con Fracción de Eyección Preservada" (ExIC-FEp) trial; and to compare these results with previous studies investigating the screening accuracy for assessing functional capacity of the 6-minute walk test in participants with other chronic cardiac pathologies through a meta-analysis. RESULTS: The ExIC-FEp trial involved 22 participants with heart failure with preserved ejection fraction, who were not treated with beta-blockers, using the cardiopulmonary exercise test, specifically VO(2max,) as the reference test. The 6-minute walk test had a sensitivity of 70%, a specificity of 80%, and an area under the curve of 76% in the ExIC-FEp trial. Five studies were included in the meta-analysis showing a sensitivity of 79%, a specificity of 78%, and an area under the curve of 85%. CONCLUSION: In conclusion, the 6-minute walk test holds promise as a screening tool for assessing functional capacity in heart failure with preserved ejection fraction and chronic heart diseases, with a VO(2max)â<â14 ml/kg/min as a reference point. It demonstrates moderate to good screening accuracy. However, the screening accuracy and optimal cut-off points of the 6-minute walk test for detecting severely reduced functional capacity, regardless of aetiology, are unclear. TRIAL REGISTRATION: NCT05726474. Registered 16 February 2023, https://clinicaltrials.gov/study/NCT05726474 .
Accuracy of the 6-Minute Walk Test for Assessing Functional Capacity in Patients With Heart Failure With Preserved Ejection Fraction and Other Chronic Cardiac Pathologies: Results of the ExIC-FEp Trial and a Meta-Analysis.
6分钟步行试验评估射血分数保留型心力衰竭和其他慢性心脏病患者功能能力的准确性:ExIC-FEp试验结果和荟萃分析
阅读:15
作者:Cavero-Redondo Iván, Saz-Lara Alicia, Bizzozero-Peroni Bruno, Núñez-MartÃnez Laura, DÃaz-Goñi Valentina, Calero-Paniagua Ismael, MatÃnez-GarcÃa Irene, Pascual-Morena Carlos
| 期刊: | Sports Medicine-Open | 影响因子: | 5.900 |
| 时间: | 2024 | 起止号: | 2024 Jun 18; 10(1):74 |
| doi: | 10.1186/s40798-024-00740-6 | 研究方向: | 心血管 |
| 疾病类型: | 心力衰竭、心脏病 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
