Tensile strain increased COX-2 expression and PGE2 release leading to weakening of the human amniotic membrane

拉伸应变增加 COX-2 表达和 PGE2 释放,导致人羊膜软化

阅读:8
作者:B Chowdhury, A L David, C Thrasivoulou, D L Becker, D L Bader, T T Chowdhury

Conclusion

A combination of inflammatory and mechanical factors may disrupt amniotic membrane biomechanics and matrix composition.

Discussion

Fibre orientation has a significant effect on amniotic strength. Tensile strain increased Cx43/COX-2 expression and PGE2 release resulting in tissue softening mediated by enhanced GAG levels and a reduction in collagen/elastin content. Conclusion: A combination of inflammatory and mechanical factors may disrupt amniotic membrane biomechanics and matrix composition.

Methods

Human amniotic membranes isolated from the cervix (CAM) or placenta regions (PAM) were examined by second harmonic generation to identify collagen orientation and subjected to tensile testing to failure. In separate experiments, specimens were subjected to cyclic tensile strain (2%, 1 Hz) for 24 h. Specimens were examined for Cx43 by immunofluorescence confocal microscopy and expression of COX-2 and Cx43 by RT-qPCR. PGE2, collagen, elastin and glycosaminoglycan (GAG) levels were analysed by biochemical assay.

Results

Values for tensile strength were significantly higher in PAM than CAM with mechanical parameters dependent on collagen orientation. Gene expression for Cx43 and COX-2 was enhanced by tensile strain leading to increased PGE2 release and GAG levels in PAM and CAM when compared to unstrained controls. In contrast, collagen and elastin content was reduced by tensile strain in PAM and CAM.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。