Current clinical practice lacks quantitative assessment methods for elbow joint movements. In response to existing research limitations, this study introduces the innovative elbow joint torque measurement device (EJTMD), which concurrently measures muscle strength and active range of motion (AROM) using a five-bar linkage system governed by a sliding mode control algorithm. Healthy subjects (nâ=â22) and stroke patients (nâ=â22) were recruited in a randomized trial. Each participant underwent two measurement. EJTMD or traditional tools like a protractor and a muscle strength tester. Participants were randomly allocated to EJTMD first or traditional tools first. The efficacy of EJTMD was assessed by comparing muscle strength and AROM with traditional tools. Integrated electromyography (iEMG) and root mean square (RMS) were used to assess the intensity of muscle activity during elbow movements. The peak torque (PT) and the ratio of peak torque to body weight (PT/BW) were examined to explore the differences in mechanical characteristics of bilateral elbow joints. Motor evoked potential (MEP) and central motor conduction time (CMCT) were employed to investigate the potential mechanisms underlying motor discrepancies post-stroke. EJTMD demonstrates superior muscle strength, AROM, iEMG, and RMS during elbow movements compared to traditional tools (Pâ<â0.05). Repeated EJTMD measurement outcomes have a good correlation on the same day (rââ¥â0.999, Pâ<â0.001). EJTMD exhibits significant differences in measurement outcomes among stroke patients before and after treatment (Pâ<â0.05), compared to traditional tools. Stroke patients exhibit reduced PT and PT/BW on the lesion side across low, medium, and high-speed tests, with a more pronounced decline observed during low-speed testing (Pâ<â0.001). Stroke patients show decreased iEMG and RMS on the affected side during elbow movements (Pâ<â0.05), with prolonged MEP latency and CMCT (Pâ<â0.001), and reduced MEP amplitude (Pâ<â0.001). Based on the results, EJTMD demonstrates reliability and effectiveness in assessing elbow movements in both healthy subjects and stroke patients, showing sensitivity to minor joint changes. Stroke patients exhibit reduced flexor and extensor function on the lesion side, potentially resulting from impaired corticospinal tract conduction.
Evaluation of a novel elbow joint torque measurement device in healthy subjects and stroke patients: a randomized trial.
对健康受试者和中风患者进行新型肘关节扭矩测量装置的评价:一项随机试验
阅读:3
作者:Xu Qingqin, Hu Mengxuan, Li Lei, Chen Shi, Liu Bo, Lu Jianwei, Chen Hemu
| 期刊: | Scientific Reports | 影响因子: | 3.900 |
| 时间: | 2025 | 起止号: | 2025 Apr 13; 15(1):12708 |
| doi: | 10.1038/s41598-025-97953-w | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。