BACKGROUND: The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. METHODS: Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. RESULTS: 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). CONCLUSIONS: The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.
Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.
毛果芸香碱离子导入汗液氯化物试验中的脉冲直流电和恒定直流电
阅读:4
作者:Gomez Carla Cristina Souza, Servidoni Maria de Fatima, Marson Fernando Augusto de Lima, Canavezi Paulo Jose Coelho, Vinagre Adriana Mendes, Costa Eduardo Tavares, Ribeiro Antonio Fernando, Ribeiro Maria Angela Gonçalves de Oliveira, Toro Adyleia Aparecida Dalbo Contrera, Pavan Celia Regina, Rondon Michelle Vivine Sá Dos Santos, Lorena Sonia Leticia Silva, Vieria Francisco Ubaldi Jr, Ribeiro Jose Dirceu
| 期刊: | BMC Pulmonary Medicine | 影响因子: | 2.800 |
| 时间: | 2014 | 起止号: | 2014 Dec 13; 14:198 |
| doi: | 10.1186/1471-2466-14-198 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。