A number of clinical, in vitro and computational studies have shown the potential for thromboembolic complications in bileaflet mechanical heart valves (BMHV), primarily due to the complex and unsteady flows in the valve hinges. These studies have focused on quantitative and qualitative parameters such as velocity magnitude, turbulent shear stresses, vortex formation, and platelet activation to identify potential for blood damage. However, experimental characterization of the whole flow fields within the valve hinges has not yet been conducted. This information can be utilized to investigate instantaneous damage to blood elements and also to validate numerical studies focusing on the hinge's complex fluid dynamics. The objective of this study was therefore to develop a high-resolution imaging system to characterize the flow fields and global velocity maps in a BMHV hinge. In this study, the steady leakage hinge flow fields representing the diastolic phase during the cardiac cycle in a 23 mm St. Jude Medical regent BMHV in the aortic position were characterized using a two-dimensional micro particle image velocimetry system. Diastolic flow was simulated by imposing a static pressure head on the aortic side. Under these conditions, a reverse flow jet from the aortic to the ventricular side was observed with velocities in the range of 1.47-3.24 m/s, whereas low flow regions were observed on the ventricular side of the hinge with viscous shear stress magnitude up to 60 N/m². High velocities and viscous shearing may be associated with platelet activation and hemolysis, while low flow zones can cause thrombosis due to increased residence time in the hinge. Overall, this study provides a high spatial resolution experimental technique to map the fluid velocity in the BMHV hinge, which can be extended to investigate micron-scale flow domains in various prosthetic devices under different hemodynamic conditions.
Micro particle image velocimetry measurements of steady diastolic leakage flow in the hinge of a St. Jude Medical® regent⢠mechanical heart valve.
利用微粒图像测速技术测量圣犹达医疗® regent™ 机械心脏瓣膜铰链处舒张期稳定漏血流量
阅读:5
作者:Jun Brian H, Saikrishnan Neelakantan, Yoganathan Ajit P
| 期刊: | Annals of Biomedical Engineering | 影响因子: | 5.400 |
| 时间: | 2014 | 起止号: | 2014 Mar;42(3):526-40 |
| doi: | 10.1007/s10439-013-0919-y | 研究方向: | 心血管 |
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。