A Flow Cytometry-Based Assay for High-Throughput Detection and Quantification of Neutrophil Extracellular Traps in Mixed Cell Populations.

基于流式细胞术的高通量检测和定量混合细胞群中中性粒细胞胞外陷阱的检测方法

阅读:3
作者:Zharkova Olga, Tay Sen Hee, Lee Hui Yin, Shubhita Tripathi, Ong Wei Yee, Lateef Aisha, MacAry Paul Anthony, Lim Lina Hsiu Kim, Connolly John Edward, Fairhurst Anna-Marie
Neutrophil extracellular traps (NETs) are web-like structures composed of decondensed chromatin and antimicrobial proteins that are released into the extracellular space during microbial infections. This active cell death program is known as NETosis. To date, florescence microscopy is the widely accepted method for visualization and quantification of NETs. However, this method is subjective, time consuming and yields low numbers of analyzed polymorphonuclear cells (PMNs) per sample. Increasing interest has emerged on the identification of NETs using flow cytometry techniques. However, flow cytometry analysis of NETs requires particular precautions for sample preparation to obtain reproducible data. Herein, we describe a flow cytometry-based assay for high-throughput detection and quantification of NETosis in mixed cell populations. We used fluorescent-labeled antibodies against cell markers on PMNs together with a combination of nucleic acid stains to measure NETosis in whole blood (WB) and purified PMNs. Using plasma membrane-impermeable DNA-binding dye, SYTOX Orange (SO), we found that cell-appendant DNA of NETting PMNs were positive for SO and DAPI. The combination of optimally diluted antibody and nucleic acid dyes required no washing and yielded low background fluorescence. Significant correlations were found for NETosis from WB and purified PMNs. We then validated the assay by comparing with time-lapse live cell fluorescence microscopy and determined very good intraassay and interassay variances. The assay was then applied to a disease associated with NETosis, systemic lupus erythematosus (SLE). We examined PMA-induced NETosis in peripheral PMNs from SLE patients and controls and in bone marrow PMNs from multiple murine models. In summary, this assay is observer-independent and allows for rapid assessment of a large number of PMNs per sample. Use of this assay does not require sophisticated microscopic equipment like imaging flow cytometers and may be a starting point to analyze extracellular trap formation from immune cells other than PMNs. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。