PCR identification of bacteria in blood culture does not fit the daily workflow of a routine microbiology laboratory

PCR 鉴定血培养中的细菌并不符合常规微生物实验室的日常工作流程

阅读:9
作者:Santra Karumaa, Pauliina Kärpänoja, Hannu Sarkkinen

Abstract

We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。