Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APD(XX). In a comparative literature research, we found that mean APD(90) in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD(90), APD(50) and APD(30), are decreased at more negative RMP (respectively HMP) values. E.g., APD(90) is shortened by â¼60% after lowering HMP from -70 mV to -90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD(50) and APD(90) were shortened. During series of APs at 1 Hz, spike duration (APD(90)) decreased by â¼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by â¼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells' threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.
Heterogeneity of ventricular action potentials in neonatal rat cardiomyocytes and methodological aspects of patch clamp measurements.
新生大鼠心肌细胞心室动作电位的异质性及膜片钳测量方法学方面
阅读:22
作者:Syren Pascal, Zlatopolskaia Anna, Bruehl Claus, Schöffel Axel, Caspari Teresa, Heà Chiara, Frey Norbert, Thomas Dierk, Lugenbiel Patrick
| 期刊: | Frontiers in Physiology | 影响因子: | 3.400 |
| 时间: | 2025 | 起止号: | 2025 Feb 21; 16:1537345 |
| doi: | 10.3389/fphys.2025.1537345 | 种属: | Rat |
| 研究方向: | 细胞生物学 | 疾病类型: | 心肌炎 |
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
