The pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has posed an enormous burden on the global public health system and has had disastrous socioeconomic consequences. Currently, single sampling tests, 20-in-1 pooling tests, nucleic acid point-of-care tests (POCTs), and rapid antigen tests are implemented in different scenarios to detect SARS-CoV-2, but a comprehensive evaluation of them is scarce and remains to be explored. In this study, 3 SARS-CoV-2 inactivated cell culture supernatants were used to evaluate the analytical performance of these strategies. Additionally, 5 recombinant SARS-CoV-2 nucleocapsid (N) proteins were also used for rapid antigen tests. For the wild-type (WT), Delta, and Omicron strains, the lowest inactivated virus concentrations to achieve 100% detection rates of single sampling tests ranged between 1.28âÃâ10(2) to 1.02âÃâ10(3), 1.28âÃâ10(2) to 4.10âÃâ10(3), and 1.28âÃâ10(2) to 2.05âÃâ10(3) copies/mL. The 20-in-1 pooling tests ranged between 1.30âÃâ10(2) to 1.04âÃâ10(3), 5.19âÃâ10(2) to 2.07âÃâ10(3), and 2.59âÃâ10(2) to 1.04âÃâ10(3) copies/mL. The nucleic acid POCTs were all 1.42âÃâ103 copies/mL. The rapid antigen tests ranged between 2.84âÃâ10(5) to 7.14âÃâ10(6), 8.68âÃâ10(4) to 7.14âÃâ10(6), and 1.12âÃâ10(5) to 3.57âÃâ10(6) copies/mL. For the WT, Delta AY.2, Delta AY.1/AY.3, Omicron BA.1, and Omicron BA.2 recombinant N proteins, the lowest concentrations to achieve 100% detection rates of rapid antigen tests ranged between 3.47 to 142.86, 1.74 to 142.86, 3.47 to 142.86, 3.47 to 142.86, and 5.68-142.86âng/mL, respectively. This study provided helpful insights into the scientific deployment of tests and recommended the full-scale consideration of the testing purpose, resource availability, cost performance, result rapidity, and accuracy to facilitate a profound pathway toward the long-term surveillance of coronavirus disease 2019 (COVID-19). IMPORTANCE In the study, we reported an evaluation of 4 detection strategies implemented in different scenarios for SARS-CoV-2 detection: single sampling tests, 20-in-1 pooling tests, nucleic acid point-of-care tests, and rapid antigen tests. 3 SARS-CoV-2-inactivated SARS-CoV-2 cell culture supernatants and 5 recombinant SARS-CoV-2 nucleocapsid proteins were used for evaluation. In this analysis, we found that for the WT, Delta, and Omicron supernatants, the lowest concentrations to achieve 100% detection rates of single sampling tests ranged between 1.28âÃâ10(2) to 1.02âÃâ10(3), 1.28âÃâ10(2) to 4.10âÃâ10(3), and 1.28âÃâ10(2) to 2.05âÃâ10(3) copies/mL. The 20-in-1 pooling tests ranged between 1.30âÃâ10(2) to 1.04âÃâ10(3), 5.19âÃâ10(2) to 2.07âÃâ10(3), and 2.59âÃâ10(2) to 1.04âÃâ10(3) copies/mL. The nucleic acid POCTs were all 1.42âÃâ10(3) copies/mL. The rapid antigen tests ranged between 2.84âÃâ10(5) to 7.14âÃâ10(6), 8.68âÃâ10(4) to 7.14âÃâ10(6), and 1.12âÃâ10(5) to 3.57âÃâ10(6) copies/mL. For the WT, Delta AY.2, Delta AY.1/AY.3, Omicron BA.1, and Omicron BA.2 recombinant N proteins, the lowest concentrations to achieve 100% detection rates of rapid antigen tests ranged between 3.47 to 142.86, 1.74 to 142.86, 3.47 to 142.86, 3.47 to 142.86, and 5.68 to 142.86âng/mL, respectively.
Evaluation of Four Strategies for SARS-CoV-2 Detection: Characteristics and Prospects.
SARS-CoV-2 检测四种策略的评估:特点和前景
阅读:4
作者:Chen Yuqing, Ma Yu, Han Yanxi, Diao Zhenli, Chang Lu, Li Jinming, Zhang Rui
| 期刊: | Microbiology Spectrum | 影响因子: | 3.800 |
| 时间: | 2022 | 起止号: | 2022 Dec 21; 10(6):e0214322 |
| doi: | 10.1128/spectrum.02143-22 | 研究方向: | 炎症/感染 |
| 疾病类型: | 新冠 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
