Analysis of diagnostic test outcomes in a large loiasis cohort from an endemic region: Serological tests are often false negative in hyper-microfilaremic infections.

阅读:4
作者:Veletzky Luzia, Eberhardt Kirsten Alexandra, Hergeth Jennifer, Stelzl Daniel Robert, Zoleko Manego Rella, Kreuzmair Ruth, Burger Gerrit, Mischlinger Johannes, McCall Matthew B B, Mombo-Ngoma Ghyslain, Adegnika Ayôla Akim, Agnandji Selidji Todagbe, Matsiegui Pierre Blaise, Lell Bertrand, Kremsner Peter, Mordmüller Benjamin, Tappe Dennis, Ramharter Michael
BACKGROUND: The parasitic disease loiasis is associated with significant morbidity and mortality. Individuals with hyper-microfilaremia (greater than 20,000 microfilariae per mL of blood) may suffer from serious treatment-related or spontaneous adverse events. Diagnosing loiasis remains complex and primarily relies on direct parasite detection. In this study, we analyzed the performance of various diagnostic tests and the influence of parasitological and clinical factors on test outcomes in samples from individuals living in an endemic region. METHODS: Data and samples were collected from rural Gabon. Loiasis was defined as either detectable microfilaremia, or a positive history of eyeworm as assessed by the RAPLOA questionnaire. Diagnostic testing included a quantitative PCR (qPCR) for detection of Loa loa DNA in blood samples, an in-house crude L. loa antigen IgG ELISA, and a rapid test for antibodies against the Ll-SXP-1 antigen (RDT). Sensitivity and specificity were determined for each test and factors potentially influencing outcomes were evaluated in an exploratory analysis. RESULTS: ELISA, RDT and qPCR results were available for 99.8%, 78.5%, and 100% of the 1,232 participants, respectively. The ELISA and RDT had only modest diagnostic accuracy. qPCR was specific for L. loa microfilaremia and Cycle threshold values correlated with microfilarial density. Anti-L. loa IgG levels were highest in occult loiasis, and antibody levels correlated inversely with L. loa microfilarial density as did RDT line intensities. Only 84.6% and 16.7% of hyper-microfilaremic individuals tested positive by ELISA (11/13) and RDT (2/12), respectively. CONCLUSION: None of the tests demonstrated high sensitivity and specificity for loiasis. Indirect diagnostic assays were characterized by low specificity. Additionally, hyper-microfilaremic individuals often tested negative by RDT and ELISA, indicating that these tests are not suitable for individual case management in endemic populations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。