Mitochondrial dysfunction contributes significantly to the development of atrial fibrillation (AF). Conflicting data regarding the atrial pacing and the risk of AF existed, and the impact of atrial pacing on mitochondrial function remains unknown. Therefore, we sought to examine the association between atrial pacing percentage and mitochondrial function in patients with cardiovascular implantable electronic devices (CIEDs) with atrial pacing capability. This is a cross-sectional study involving 183 patients with CIEDs with atrial pacing capability. The oxidative stress and mitochondrial function were determined in peripheral blood mononuclear cells (PBMCs). Among 183 patients, 55.7% had permanent pacemakers, 7.7% had defibrillators, and 36.6% had cardiac resynchronization therapy. Mean age was 67.5 ± 14.7 yr with 51% being male. Mean left ventricular ejection fraction (LVEF) was 53.9 ± 16.8%. We demonstrated that the presence of atrial pacing above 50% correlated with higher levels of mitochondrial spared respiratory capacity (P = 0.043) and coupling efficiency (P = 0.045). After adjusting with multiple linear regression for age, sex, LVEF, history of AF, sick sinus syndrome, comorbidities, estimated glomerular filtration rate (eGFR), cardiac resynchronization therapy (CRT), and percentage of ventricular pacing, our findings revealed a statistically significant association between a higher percentage of atrial pacing and increased spared respiratory capacity (β, 0.217, P = 0.046), lower nonmitochondrial respiration (β, -0.230; P = 0.023), and proton leak (β, -0.247; P = 0.022). We demonstrated that atrial pacing enhances mitochondrial performance in PBMCs and left ventricular contractile performance in patients with CIEDs. This observation may serve as an additional support for the preventive effect of atrial pacing in the prevention of atrial arrhythmia.NEW & NOTEWORTHY Atrial pacing enhances mitochondrial spare respiratory capacity and reduces proton leak. This finding may provide further evidence supporting the preventive role of atrial pacing in reducing the risk of atrial fibrillation in patients with cardiac implantable electronic devices.
Atrial pacing improves mitochondrial function in peripheral blood mononuclear cells in patients with cardiac implantable electronic devices.
阅读:3
作者:Nantsupawat Teerapat, Gumrai Pawut, Apaijai Nattayaporn, Phrommintikul Arintaya, Prasertwitayakij Narawudt, Chattipakorn Siriporn C, Chattipakorn Nipon, Wongcharoen Wanwarang
| 期刊: | American Journal of Physiology-Heart and Circulatory Physiology | 影响因子: | 4.100 |
| 时间: | 2024 | 起止号: | 2024 Nov 1; 327(5):H1146-H1152 |
| doi: | 10.1152/ajpheart.00537.2024 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
