A stereoselective assay was developed for the quantification of bupropion and oxidative, reductive, and glucuronide metabolites (16 analytes total) in human urine. Initially, authentic glucuronide standards obtained from commercial sources were found to be incorrectly labeled with regard to stereochemistry; the correct stereochemistry was unequivocally reassigned. A trifurcated urine sample preparation and analysis procedure was employed for the stereoselective analysis of bupropion, hydroxybupropion, erythrohydrobupropion, and threohydrobupropion enantiomers, and hydroxybupropion, erythrohydrobupropion and threohydrobupropion β-d-glucuronide diastereomers in urine. Method 1 stereoselectively analyzed bupropion (R and S), and unconjugated free hydroxybupropion (R,R and S,S), erythrohydrobupropion (1R,2S and 1S,2R), and threohydrobupropion (1R,2R and 1S,2S) using chiral chromatography with an α1-acid glycoprotein column. Because no hydroxybupropion β-d-glucuronide standards were commercially available, method 2 stereoselectively analyzed total hydroxybupropion aglycones (R,R and S,S-hydroxybupropion) after urine hydrolysis by β-glucuronidase. Hydroxybupropion β-d-glucuronide (R,R and S,S) urine concentrations were calculated as the difference between total and free hydroxybupropion (R,R and S,S) concentrations. Due to incomplete β-glucuronidase hydrolysis of erythrohydrobupropion and threohydrobupropion β-d-glucuronide diastereomers, method 3 stereoselectively analyzed intact erythrohydrobupropion and threohydrobupropion β-d-glucuronide diastereomers using C18 column chromatography. All analytes were quantified by positive ion electrospray tandem mass spectrometry. The assay was fully validated over analyte-specific concentrations. Intra- and inter assay precision were within 15% for each analyte. The limits of quantification for bupropion (R and S), hydroxybupropion (R,R and S,S), threohydrobupropion (1S,2S and 1R,2R), erythrohydrobupropion (1R,2S and 1S,2R) were 10, 50, 100, and 100ng/mL, respectively. The limits of quantification for (1R,2R)-threohydrobupropion β-d-glucuronide, (1S,2S)-threohydrobupropion β-d-glucuronide, and (1R,2R)-erythrohydrobupropion β-d-glucuronide were each 50ng/mL. Due to the abundance of bupropion and metabolites in human urine, no efforts were made to optimize sensitivity. All analytes were stable following freeze thaw cycles at -80°C. This assay was applicable to clinical pharmacokinetic investigations of bupropion in patients and to in vitro metabolism of the primary bupropion metabolites to their glucuronides.
Development, validation and application of a comprehensive stereoselective LC/MS-MS assay for bupropion and oxidative, reductive, and glucuronide metabolites in human urine.
阅读:4
作者:Teitelbaum Aaron M, Flaker Alicia M, Kharasch Evan D
| 期刊: | Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences | 影响因子: | 2.800 |
| 时间: | 2016 | 起止号: | 2016 Aug 1; 1027:239-53 |
| doi: | 10.1016/j.jchromb.2016.05.036 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
