Multi-institutional study on image quality for a novel CBCT solution on O-ring linac.

阅读:7
作者:Agulles-Pedrós Luis, MacDonald R Lee, Cherpak Amanda Jean, Dixit Nayha, Dong Lei, Zhao Tianyu, Thind Kundan, Doemer Anthony, Teo Boon-Keng, Su Shiqin, Moncion Alexander, Robar James L
INTRODUCTION: This work presents a multi-institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions. METHODS: Phantoms for measuring relative electron density (RED) and image quality were sent to six institutions for imaging on Ethos and Halcyon units equipped with HyperSight CBCT. The imaging protocols included tube potential from 100 to 140 kVp and exposure from 80 to 800 mAs. Imaging performance was evaluated with regard to RED versus Hounsfield units (HU), uniformity, contrast-to-noise ratio (CNR), slice thickness, circular symmetry, modulation transfer function (MTF), and spatial resolution. RESULTS: Among all institutions, some variability was observed among institutions in the RED-to-HU relationship, especially for RED values greater than 1, although no outliers were found (|z-score| < 2 in all cases). In this range, RED/HU slopes were 475 ± 25 10(-6) RED/HU at 100kVp, 505 ± 20 10(-6) RED/HU at 125kVp, and 550 ± 20 10(-6) RED/HU at 140kVp. Radial uniformity ranged from 1 to 7 HU, depending on protocol. Circular symmetry for two points 50 mm apart showed consistency within one-pixel dimension. Integral nonuniformity was between 1 and 10, with no difference observed between vertical and horizontal dimensions. Contrast rods with 1% gave CNR = 0.5, 1 and 2 for 100(88), 125(176), and 140(528) in kVp(mAs), and contrast rods with 0.5% had CNR = 0.2, 0.4 and 0.8 for 100(88), 125(176), and 140(528) in kVp(mAs). Spatial resolution given by MTF at 10% and 50% yielded values of 0.55 ± 0.01 mm(-1) and 0.35 ± 0.02 mm(-1), respectively. CONCLUSIONS: This multi-institutional analysis of CBCT imaging performance showed consistency in radial uniformity, circular symmetry, integral nonuniformity, contrast, and spatial resolution. Some variability was seen in the RED-to-HU relationship for RED > 1 depending on exposure. More data from different institutions would be necessary to establish more robust statistical metrics, which ensure quality parameters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。