An isocratic reverse-phase high-performance liquid chromatography (RP-HPLC) method, coupled with photodiode array detection (PDA), was developed for the identification and characterization of stress degradation products and an unknown process-related impurity of rivaroxaban in bulk drug form. Rivaroxaban, a selective and direct Factor Xa inhibitor, underwent forced degradation under hydrolytic (acidic, alkaline, and neutral), photolytic, thermal, and oxidative stress conditions, following the ICH's guidelines. The drug displayed significant susceptibility to acid, base, and oxidative environments leading to the formation of eleven degradation products. All degradation products, along with process impurities and Rivaroxaban, were effectively separated using a (4.6 à 250 mm, 5 µm) C18 Thermo ODS Hypersil column at ambient temperature. The mobile phase composed of acetonitrile and monobasic potassium phosphate (pH 2.9) in a 30:70 (v/v) ratio, with a flow rate of 1.0 mL/min, and detection was carried out at 249 nm. The LC-PDA method was validated in accordance with the ICH's guidelines and USP38-NF33, demonstrating specificity, linearity, accuracy, precision, and robustness. Recovery studies showed results within the range of 98.6-103.4%, with a % RSD LT 2%. The limits of detection (LOD) and quantitation (LOQ) for rivaroxaban were determined to be 0.30 ppm and 1.0 ppm, respectively. Stress studies confirmed that the degradation products did not interfere with rivaroxaban detection, establishing the method as stability-indicating. Specific impurities were identified, including impurity G at 2.79 min, impurity D at 3.50 min, impurity H at 5.32 min, impurity C at 6.14 min, impurity E at 8.36 min, impurity A at 9.03 min, and impurity F at 9.49 min. Additionally, several unknown impurities were observed at 3.20, 4.00, 4.59, and 4.77 min. Statistical evaluation confirmed the method's reliability, making it suitable for routine analysis, quality control of raw materials, formulations of varying strengths, dissolution studies, and bioequivalence assessments of rivaroxaban formulations.
Optimized and Validated Stability-Indicating RP-HPLC Method for Comprehensive Profiling of Process-Related Impurities and Stress-Induced Degradation Products in Rivaroxaban (XARELTO)(®).
阅读:10
作者:Mestareehi, Aktham, H
| 期刊: | International Journal of Molecular Sciences | 影响因子: | 4.900 |
| 时间: | 2025 | 起止号: | 2025 May 15; 26(10):4744 |
| doi: | 10.3390/ijms26104744 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。