Cardiotoxicity remains a major challenge in drug development, accounting for 45% of medication withdrawals due to cardiac ischemia and arrhythmogenicity. To overcome the limitations of traditional multielectrode array (MEA)-based cardiotoxicity assays, we developed a Nafion-coated NanoMEA platform with decoupled reference electrodes, offering enhanced sensitivity for electrophysiological measurements. The 'Decoupled' configuration significantly reduced polarization resistance (Rp) from 12.77 MΩ to 3.41 MΩ, improving charge transfer efficiency as demonstrated by electrochemical impedance spectroscopy and cyclic voltammetry. Additionally, the limit of detection significantly decreased from 0.175 MΩ (Coupled) to 0.040 MΩ (Decoupled), underscoring the system's enhanced sensitivity. Using human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), we evaluated the effects of three proarrhythmic drugs: Ranolazine, Domperidone, and Sotalol. Under the decoupled condition, the platform exhibited reductions in IC50 values for Domperidone (0.71 μM-0.29 μM), Sotalol (7.61 μM-0.27 μM), and Ranolazine (53.08 μM-5.89 μM), demonstrating significantly improved drug detection sensitivity. Longitudinal analysis revealed significant alterations in key electrophysiological parameters, including beating period (BP), field potential duration (FPD), spike slope, and amplitude, which were consistent with the known pharmacological actions of these drugs. Further validation through action potential (AP) waveform analysis showed enhanced repolarization dynamics, confirming the platform's predictive capabilities. Our findings highlight the critical role of electrochemical topology in optimizing MEA performance. The NanoMEA system, featuring decoupled Nafion-coated electrodes, represents a robust and sensitive platform for cardiotoxicity screening, setting a new standard for preclinical drug safety assessment and advancing bioelectronic device design for cardiac research.
Effect of electrochemical topology on detection sensitivity in MEA assay for drug-induced cardiotoxicity screening.
阅读:4
作者:Kim Byunggik, Choi Jong Seob, Zhu Yiguang, Kim Juhyun, Kim Ye Seul, Parra Andres, Locke Paul A, Kim Jae Ho, Herron Todd, Kim Deok-Ho
| 期刊: | Biosensors & Bioelectronics | 影响因子: | 10.500 |
| 时间: | 2025 | 起止号: | 2025 Mar 15; 272:117082 |
| doi: | 10.1016/j.bios.2024.117082 | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。
