Purpose: The purpose of this study was to investigate the impact of a new arterial intravascular pump on the hemodynamic surroundings within the aorta. Methods: A new arterial intravascular pump was placed in the descending aorta, and the effects of three positions within the aorta, as well as the number (n = 1 to 3) of pumps, on arterial flow features, organ perfusion, and blood trauma were investigated using a computational fluid dynamics (CFD) method. Results: It was found that as the pump position was moved backward, the perfusion in the three bifurcated vessels of the aorta arch increased and the pump suction flow decreased, resulting in a reduced high shear stress and decreased residence time in the three branches of the aortic arch. The further posterior the location of the pump, the better the blood flow perfusion to the kidneys, while the perfusion at the bifurcation of the abdominal aorta was reduced, due to the pump suction effect. Compared to the condition with single pump support, the multi-pump assist model can significantly reduce the pump rotating speed, while keeping the same flow patterns, leading to a decreased volume of high shear stress and flow loss. When increasing the number of pumps, the perfusion to the three branches of the aortic arch increased, accompanied by a diminished residence time, and the perfusion to the other aortic branches was decreased. However, the perfusion to the other aortic branches, especially for the renal arteries and even under a three-pump condition, was close to that without pump assistance. Conclusion: The placement of an intravascular pump near the beginning of the suprarenal abdominal aorta was considered the optimal location, in order to improve the hemodynamic surroundings. Increasing the number of pumps can significantly reduce the rotational speed, while maintaining the same flowrate, with a decreased fluid energy loss and a reduced high shear stress. This arterial intravascular pump can effectively improve renal blood flow.
The Impact of a New Arterial Intravascular Pump on Aorta Hemodynamic Surrounding: A Numerical Study.
阅读:3
作者:Li Yuan, Xi Yifeng, Wang Hongyu, Sun Anqiang, Deng Xiaoyan, Chen Zengsheng, Fan Yubo
| 期刊: | Bioengineering-Basel | 影响因子: | 3.800 |
| 时间: | 2022 | 起止号: | 2022 Oct 13; 9(10):547 |
| doi: | 10.3390/bioengineering9100547 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
