Development and use of flow cytometry for detection of airborne fungi.

阅读:4
作者:Prigione Valeria, Lingua Guido, Marchisio Valeria Filipello
Traditional methods for the enumeration of airborne fungi are slow, tedious, and rather imprecise. In this study, the possibility of using flow cytometry (FCM) for the assessment of exposure to the fungus aerosol was evaluated. Epifluorescence microscopy direct counting was adopted as the standard for comparison. Setting up of the method was achieved with pure suspensions of Aspergillus fumigatus and Penicillium brevicompactum conidia at different concentrations, and then analyses were extended to field samples collected by an impinger device. Detection and quantification of airborne fungi by FCM was obtained combining light scatter and propidium iodide red fluorescence parameters. Since inorganic debris are unstainable with propidium iodide, the biotic component could be recognized, whereas the preanalysis of pure conidia suspensions of some species allowed us to select the area corresponding to the expected fungal population. A close agreement between FCM and epifluorescence microscopy counts was found. Moreover, data processing showed that FCM can be considered more precise and reliable at any of the tested concentrations.