The agar dilution method (ADM) recommended for IV fosfomycin (IV FOS) is complex and labor-intensive. Keeping in mind the reality of everyday laboratory work, we have evaluated the agreement of IV FOS susceptibility results obtained using the E-test and the Phoenix system with the results obtained using the ADM. MATERIALS AND METHODS: The tests were performed on 860 strains. To evaluate susceptibility to IV FOS, BioMerieux E-tests (bioMerieux, Warsaw, Poland), BD Phoenix panels (BD Phoenix, Sparks, MD, USA), and the ADM were used. Clinical interpretation was performed in accordance with EUCAST Guidance (v12.0, 2021). The significance of the E-test and the Phoenix was analyzed in relation to the ADM by defining categorical agreement (CA), major error (ME), and very major error (VME). Essential agreement (EA) has also been defined for the E-test. A method was considered reliable, in accordance with ISO 20776-2:2007, when CA and EA were above 89.9% and VME was <3%. RESULTS: A categorical agreement of >98.9% was demonstrated between the E-test and the ADM for overall strains and for Echerichia coli, ESBL-producing Enterobacterales, and Staphylococcus aureus, while between the Phoenix and the ADM, a CA of >98.9% was shown only for Escherichia coli, Staphylococcus aureus, and Proteus spp. A very major error rate of <3% was obtained only for Staphylococcus aureus and MBL-producing Pseudomonas evaluated by both the E-test and the Phoenix. An essential agreement of >98.9% between the E-test and the ADM has not been demonstrated for any of the tested groups of strains. The Phoenix yielded more VMEs than the E-test (50 and 46, respectively). The highest VME rate was demonstrated using the Phoenix method for Enterobacter spp. (53.83%). CONCLUSIONS: Both the E-test and the Phoenix have turned out to be reliable in assessing IV FOS susceptibility only for Staphylococcus aureus (CA > 89.9% and VME < 3%). For the remaining tested groups of strains and genera, the simultaneous high CA rate and low VME rate required by ISO were not achieved. Both methods fared particularly badly in detecting strains resistant to IV.
Reliability of E-Tests and the Phoenix Automated Method in Assessing Susceptibility to IV Fosfomycin-Comparative Studies Relative to the Reference Method.
阅读:3
作者:Kowalska-Krochmal Beata, MÄ czyÅska Beata, Smutnicka Danuta, Secewicz Anna, Krochmal Grzegorz, Laufer Klaudyna, Dudek-Wicher Ruth
| 期刊: | Pathogens | 影响因子: | 3.300 |
| 时间: | 2023 | 起止号: | 2023 May 12; 12(5):700 |
| doi: | 10.3390/pathogens12050700 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。