Human interaural time difference thresholds for sine tones: the high-frequency limit.

阅读:3
作者:Brughera Andrew, Dunai Larisa, Hartmann William M
The smallest detectable interaural time difference (ITD) for sine tones was measured for four human listeners to determine the dependence on tone frequency. At low frequencies, 250-700 Hz, threshold ITDs were approximately inversely proportional to tone frequency. At mid-frequencies, 700-1000 Hz, threshold ITDs were smallest. At high frequencies, above 1000 Hz, thresholds increased faster than exponentially with increasing frequency becoming unmeasurably high just above 1400 Hz. A model for ITD detection began with a biophysically based computational model for a medial superior olive (MSO) neuron that produced robust ITD responses up to 1000 Hz, and demonstrated a dramatic reduction in ITD-dependence from 1000 to 1500 Hz. Rate-ITD functions from the MSO model became inputs to binaural display models-both place based and rate-difference based. A place-based, centroid model with a rigid internal threshold reproduced almost all features of the human data. A signal-detection version of this model reproduced the high-frequency divergence but badly underestimated low-frequency thresholds. A rate-difference model incorporating fast contralateral inhibition reproduced the major features of the human threshold data except for the divergence. A combined, hybrid model could reproduce all the threshold data.