The smallest detectable interaural time difference (ITD) for sine tones was measured for four human listeners to determine the dependence on tone frequency. At low frequencies, 250-700 Hz, threshold ITDs were approximately inversely proportional to tone frequency. At mid-frequencies, 700-1000 Hz, threshold ITDs were smallest. At high frequencies, above 1000 Hz, thresholds increased faster than exponentially with increasing frequency becoming unmeasurably high just above 1400âHz. A model for ITD detection began with a biophysically based computational model for a medial superior olive (MSO) neuron that produced robust ITD responses up to 1000âHz, and demonstrated a dramatic reduction in ITD-dependence from 1000 to 1500âHz. Rate-ITD functions from the MSO model became inputs to binaural display models-both place based and rate-difference based. A place-based, centroid model with a rigid internal threshold reproduced almost all features of the human data. A signal-detection version of this model reproduced the high-frequency divergence but badly underestimated low-frequency thresholds. A rate-difference model incorporating fast contralateral inhibition reproduced the major features of the human threshold data except for the divergence. A combined, hybrid model could reproduce all the threshold data.
Human interaural time difference thresholds for sine tones: the high-frequency limit.
阅读:3
作者:Brughera Andrew, Dunai Larisa, Hartmann William M
| 期刊: | Journal of the Acoustical Society of America | 影响因子: | 2.300 |
| 时间: | 2013 | 起止号: | 2013 May;133(5):2839-55 |
| doi: | 10.1121/1.4795778 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
