Typically, bones are harvested at the time of animal euthanasia and stored until mechanical testing. However, storage methods are not standardized, and differential effects on mechanical properties are possible between methods. The goal of this study was to investigate the effects that two common preservation methods (freezing wrapped in saline-soaked gauze and refrigerating ethanol fixed samples) have on bone mechanical properties in the context of an in vitro ribosylation treatment designed to modify mechanical integrity. It was hypothesized that there would be an interactive effect between ribose treatment and preservation method. Tibiae from twenty five 11week old female C57BL/6 mice were separated into 2 preservation groups. Micro-CT scans of contralateral pairs assessed differences in geometry prior to storage. After 7weeks of storage, bones in each pair of tibiae were soaked in a solution containing either 0M or 0.6M ribose for 1week prior to 4 point bending tests. There were no differences in any cortical geometric parameters between contralateral tibiae. There was a significant main effect of ethanol fixation on displacement to yield (-16.3%), stiffness (+24.5%), strain to yield (-13.9%), and elastic modulus (+18.5%) relative to frozen specimens. There was a significant main effect of ribose treatment for yield force (+13.9%), ultimate force (+9.2%), work to yield (+22.2%), yield stress (+14.1%), and resilience (+21.9%) relative to control-soaked bones. Postyield displacement, total displacement, postyield work, total work, total strain, and toughness were analyzed separately within each preservation method due to significant interactions. For samples stored frozen, all six properties were lower in the ribose-soaked group (49%-68%) while no significant effects of ribose were observed in ethanol fixed bones. Storage in ethanol likely caused changes to the collagen matrix which prevented or masked the embrittling effects of ribosylation that were seen in samples stored frozen wrapped in saline-soaked gauze. These data illustrate the clear importance of maintaining hydration if the eventual goal is to use bones for mechanical assessments and further show that storage in ethanol can alter potential to detect effects of experimental manipulation (in this case ribosylation).
Even with rehydration, preservation in ethanol influences the mechanical properties of bone and how bone responds to experimental manipulation.
阅读:3
作者:Vesper Evan O, Hammond Max A, Allen Matthew R, Wallace Joseph M
| 期刊: | Bone | 影响因子: | 3.600 |
| 时间: | 2017 | 起止号: | 2017 Apr;97:49-53 |
| doi: | 10.1016/j.bone.2017.01.001 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
