We assessed the analytical performance of metagenomic workflows using NIST Reference Material (RM) 8376 DNA from bacterial pathogens spiked into two simulated clinical samples: cerebrospinal fluid (CSF) and stool. Sequencing and taxonomic classification were used to generate signals for each sample and taxa of interest and to estimate the limit of detection (LOD), the linearity of response, and linear dynamic range. We found that the LODs for taxa spiked into CSF ranged from approximately 100 to 300 copy/mL, with a linearity of 0.96 to 0.99. For stool, the LODs ranged from 10 to 221 kcopy/mL, with a linearity of 0.99 to 1.01. Furthermore, discriminating different E. coli strains proved to be workflow-dependent as only one classifier:database combination of the three tested showed the ability to differentiate the two pathogenic and commensal strains. Surprisingly, when we compared the linear response of the same taxa in the two different sample types, we found those functions to be the same, despite large differences in LODs. This suggests that the "agnostic diagnostic" theory for metagenomics (i.e., any organism can be identified because DNA is the measurand) may apply to different target organisms and different sample types. Because we are using RMs, we were able to generate quantitative analytical performance metrics for each workflow and sample set, enabling relatively rapid workflow screening before employing clinical samples. This makes these RMs a useful tool that will generate data needed to support the translation of metagenomics into regulated use.IMPORTANCEAssessing the analytical performance of metagenomic workflows, especially when developing clinical diagnostics, is foundational for ensuring that the measurements underlying a diagnosis are supported by rigorous characterization. To facilitate the translation of metagenomics into clinical practice, workflows must be tested using control samples designed to probe the analytical limitations (e.g., limit of detection). Spike-ins allow developers to generate fit-for-purpose control samples for initial workflow assessments and inform decisions about further development. However, clinical sample types include a wide range of compositions and concentrations, each presenting different detection challenges. In this work, we demonstrate how spike-ins elucidate workflow performance in two highly dissimilar sample types (stool and CSF), and we provide evidence that detection of individual organisms is unaffected by background sample composition, making detection sample-agnostic within a workflow. These demonstrations and performance insights will facilitate the translation of the technology to the clinic.
Analytical assessment of metagenomic workflows for pathogen detection with NIST RM 8376 and two sample matrices.
阅读:4
作者:Kralj Jason G, Servetas Stephanie L, Forry Samuel P, Hunter Monique E, Dootz Jennifer N, Jackson Scott A
| 期刊: | Microbiology Spectrum | 影响因子: | 3.800 |
| 时间: | 2025 | 起止号: | 2025 Apr;13(4):e0280624 |
| doi: | 10.1128/spectrum.02806-24 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。