HPLC Method for Quantification of Caffeine and Its Three Major Metabolites in Human Plasma Using Fetal Bovine Serum Matrix to Evaluate Prenatal Drug Exposure.

采用胎牛血清基质对人血浆中咖啡因及其三种主要代谢物进行定量分析的高效液相色谱法,用于评估产前药物暴露

阅读:6
作者:Lopez-Sanchez Rosa Del Carmen, Lara-Diaz Victor Javier, Aranda-Gutierrez Alejandro, Martinez-Cardona Jorge A, Hernandez Jose A
Caffeine is recognized as the first-line therapeutic agent for apnea of prematurity. The dosage regimen is 10 mg/kg loading dose and 2.5 mg/kg maintenance dose. However, the plasma concentration achieved, not always, is therapeutically useful. It makes necessary to increase the doses to reach plasma concentration up to 30 or 35 μg/mL or even higher to attain therapeutic effect. To study why neonates have these differences, and whether these effects are linked to prenatal caffeine exposure, we had to develop an analytical method for an accurate measurement of caffeine and metabolites concentration. The analysis was carried out using fetal bovine serum (FBS) as biological matrix in a high-performance liquid chromatography with an ultraviolet detector method. This method allows acceptable chromatographic resolution between analytes in 15 minutes. It was validated and proved to be linear in the 0.1-40 µg/mL range for caffeine, paraxanthine, theobromine, and theophylline in the same chromatographic analysis. Accuracy for quality control samples for intra- and interday assays was ranged from 96.5 to 105.2% and 97.1 to 106.2%. Precision had CV no more than 10% in all concentration levels for all analytes. No differences were observed between quantification in human and FBS. This method was applied to quantify plasma drug concentration in mothers and their newborns in a Mexican northeast population. In our study, we confirmed self-reported caffeine maternal intake in 85.2% (n=23); meanwhile, in their newborn's plasma, it was detected only in 78% (n=21). Caffeine plasma concentrations in mother and newborn had a linear relationship, and no differences were observed between groups (mothers versus children). These results suggest that our analytical method and substitution of biological matrix was linear, precise, and accurate for caffeine quantification and could be used for measuring prenatal exposure and let us to study, in the future, concentration differences observed during apnea clinical treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。