[A fluorometric method for direct detection of inorganic polyphosphate in enterohemorrhagic Escherichia coli O157:H7].

[一种直接检测肠出血性大肠杆菌O157:H7中无机多聚磷酸盐的荧光法]

阅读:3
作者:Du Yanli, Han Zongli, Wang Xiangyu, Wan Chengsong
OBJECTIVE: To establish a quantitative fluorescent detection method using DAPI for detecting inorganic polyphosphate (polyP) in enterohemorrhagic Escherichia coli (EHEC) O157:H7. METHODS: The DNA of wild-type strain of EHEC O157:H7 was extracted and purified. DAPI was combined with the extracted DNA and polyP45 standards for measurement of the emission spectra at 360 nm and 415 nm fluorescence spectrophotometry. The fluorescence of DAPI-DNA and DAPI-polyP complexes was detected by fluorescence confocal microscopy to verify the feasibility of DAPI for detecting polyP. To determine the optimal pretreatment protocol for improving the cell membrane permeability, the effects of 6 pretreatments of the cells (namely snap-freezing in liquid nitrogen, freezing at -80 ℃, and freezing at -20 ℃, all followed by thawing at room temperature; heating at 60 ℃ for 10 min; treatment with Triton x-100; and placement at room temperature) were tested on the survival of EHEC O157:H7. The fluorescence values of the treated bacteria were then measured after DAPI staining. A standard calibration curve of polyP standard was established for calculation of the content of polyP in the live cells of wildtype EHEC strain and two ppk1 mutant strains. RESULTS: At the excitation wavelength of 360 nm, the maximum emission wavelength of DAPI-DNA was 460 nm, and the maximum emission wavelength of DAPI-polyP was 550 nm at the excitation wavelength of 415 nm. The results of confocal microscopy showed that 405 nm excitation elicited blue fluorescence from DAPIDNA complex with the emission wavelength of 425-475 nm; excitation at 488 nm elicited green fluorescence from the DAPIpolyP complex with the emission wavelength of 500-560 nm of. Snap-freezing of cells at -80 ℃ followed by thawing at room temperature was the optimal pretreatment to promote DAPI penetration into the live cells. The standard calibration curve was Y=1849X+127.5 (R(2)=0.991) was used for determining polyP content in the EHEC strains. The experimental results showed that wild-type strain had significantly higher polyP content than the mutant strains with ppk1 deletion. CONCLUSIONS: We established a convenient quantitative method for direct and reliable detection polyP content to facilitate further study of polyP and its catalytic enzymes in EHEC O157:H7.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。