A new diagnostic tool for rapid and accurate detection of Mycobacterium tuberculosis.

一种用于快速、准确检测结核分枝杆菌的新型诊断工具

阅读:4
作者:Nour-Neamatollahi Ali, Siadat Seyed Davar, Yari Shamsi, Tasbiti Alireza Hadizadeh, Ebrahimzadeh Nayereh, Vaziri Farzam, Fateh Abolfazl, Ghazanfari Morteza, Abdolrahimi Farid, Pourazar Shahin, Bahrmand Ahmadreza
Mycobacterium tuberculosis, acid fast bacilli from the family of Mycobacteriaceae, is the causative agent of most cases of tuberculosis. Tuberculosis, as a communicable disease, remains a serious public health threat, killing more than one million people globally every year. Primary diagnosis of tuberculosis bacilli (TB) relies mainly on microscopic detection of acid fast bacilli (AFB), but the method suffers from low sensitivity and the results largely depend on the technician's skill. New diagnostic tools are necessary to be introduced for rapid and accurate detection of the bacilli in sputum samples. We, in collaboration with Anda Biologicals, have developed a new platform, named as "Patho-tb", for rapid detection of AFB with high sensitivity and with low dependence on human skills. Evaluation of Patho-tb test performance was done in two settings: (1) primary field study conducted using 38 sputa from high TB prevalence area of Iran (Zabol city near to the Afghanistan border), and (2) main study conducted using 476 sputa from Tehran, capital of Iran. Patho-tb was applied for processed sputum samples in parallel with routine diagnostic methods (including AFB microscopy, culture and PCR). All test results were compared to final clinical diagnostic state of an individual and diagnostic sensitivity (DSe), specificity, positive predictive value, negative predictive value and accuracy of each test results were calculated using standard formulations. Analytical sensitivity and specificity of the Patho-tb test were also determined. Calculated values for five above mentioned parameters are as follows: for field study: AFB (DSe: 29.6, DSp: 81.8, PPV: 80, NPV: 23.1, AC: 44.7), Patho-tb (DSe: 63, DSp: 72.7, PPV: 85, NPV: 44.4, AC: 65.8), and for main study: AFB (DSe: 86.1, DSp: 99.4, PPV: 98.5, NPV: 93.9, AC: 95.2), Patho-tb (DSe: 97.4, DSp: 92.9, PPV: 86.5, NPV: 98.7, AC: 94.3). Reproducibility of Patho-tb test results were near to 100% (Cohen's kappa value between 0.85 and 1). The detection limit of Patho-tb test with 100% positivity rate was 3 × 10(3) cells/ml of sputum. In the field study, Patho-tb test was 33.4% more sensitive than AFB microscopy, while the improvement was only 11.3% during the main study. Patho-tb results are easy to interpret and the test can be merged with other screening tests, like AFB. Totally, Patho-tb test alone or in conjunction with AFB microscopy is a useful screening tool for TB detection especially in poor geographical lab conditions.

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。