Interactions between multiple cell types in parallel microfluidic channels: monitoring platelet adhesion to an endothelium in the presence of an anti-adhesion drug.

平行微流控通道中多种细胞类型之间的相互作用:在抗粘附药物存在的情况下监测血小板粘附于内皮细胞的情况

阅读:4
作者:Ku Chia-Jui, D'Amico Oblak Teresa, Spence Dana M
A simple method for immobilizing endothelial cells in the channels of a microfluidic device fabricated with soft lithography is presented that requires no surface oxidation of the substrate material used in conjunction with the microfluidic device and is operable even with a reversible seal. Specifically, optimal conditions for culturing bovine pulmonary artery endothelial cells (bPAECs) to the surface of a Petri dish were investigated. The parameters investigated included fibronectin concentration, temperature, seeding density, and immobilization time. To enhance the utility of the device, all optimization studies, and studies involving platelet adhesion to the immobilized endothelium, were performed in parallel channels, thereby enabling improved throughput over a single channel device. The optimal conditions for cell immobilization included coating the Petri dish with 100 microg/mL fibronectin, a seeding cell density of 1.00 x 10(5) cells mL(-1), and an immobilization time of 90 min at 37 degrees C. The device was then employed to monitor the physical interaction (adhesion) of platelets to the immobilized endothelium in the presence of a known platelet activator (ADP) and a drug inhibitor of platelet activation. The number of platelets adhering to the endothelial cells in the channels increased from 17.0 +/- 2.3 in the absence of ADP to 63.2 +/- 2.4 in the presence of 5.00 microM ADP. Moreover, the data presented here also shows that inhibition of endothelium nitric oxide (NO) production, a recognized inhibitor of platelet adhesion to the endothelium, increased the number of platelets adhering to the surface to 35.4 +/- 1.0. In the presence of NO inhibition and 5.00 microM ADP, the affect on platelet adhesion was further increased to 127 +/- 5.2. Finally, this device was employed to investigate the effect of a drug known to inhibit platelet adhesion (clopidogrel) and, in the presence of the drug, the platelet adhesion due to activation by 5.00 microM ADP decreased to 24.0 +/- 3.8. This work is the first representation of multiple cell types physically interacting in the channels of a microfluidic device and further demonstrates the potential of these devices in the drug discovery process and drug efficacy studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。