The rapid kinetics of biological processes and associated short-lived conformational changes pose a significant challenge in attempts to structurally visualize biomolecules during a reaction in real time. Conventionally, on-pathway intermediates have been trapped using chemical modifications or reduced temperature, giving limited insights. Here, we introduce a time-resolved cryo-EM method using a reusable PDMS-based microfluidic chip assembly with high reactant mixing efficiency. Coating of PDMS walls with SiO(2) virtually eliminates non-specific sample adsorption and ensures maintenance of the stoichiometry of the reaction, rendering it highly reproducible. In an operating range from 10 to 1,000 ms, the device allows us to follow in vitro reactions of biological molecules at resolution levels in the range of 3 à . By employing this method, we show the mechanism of progressive HflX-mediated splitting of the 70S E. coli ribosome in the presence of the GTP via capture of three high-resolution reaction intermediates within 140 ms.
Time resolution in cryo-EM using a PDMS-based microfluidic chip assembly and its application to the study of HflX-mediated ribosome recycling.
利用基于 PDMS 的微流控芯片组件实现冷冻电镜的时间分辨率及其在 HflX 介导的核糖体回收研究中的应用
阅读:10
作者:Bhattacharjee Sayan, Feng Xiangsong, Maji Suvrajit, Dadhwal Prikshat, Zhang Zhening, Brown Zuben P, Frank Joachim
| 期刊: | Cell | 影响因子: | 42.500 |
| 时间: | 2024 | 起止号: | 2024 Feb 1; 187(3):782-796 |
| doi: | 10.1016/j.cell.2023.12.027 | ||