To overcome the limited sensitivity of phone cameras for mobile health (mHealth) fluorescent detection, we have previously developed a capillary array which enables a â¼100 à increase in detection sensitivity. However, for an effective detection platform, the optical configuration must allow for uniform measurement sensitivity between channels when using such a capillary array sensor. This is a challenge due to the parallax inherent in imaging long parallel capillary tubes with typical lens configurations. To enable effective detection, we have developed an orthographic projection system in this work which forms parallel light projection images from the capillaries using an object-space telecentric lens configuration. This optical configuration results in a significantly higher degree of uniformity in measurement between channels, as well as a significantly reduced focal distance, which enables a more compact sensor. A plano-convex lens (f=150 mm) was shown to produce a uniform orthographic projection when properly combined with the phone camera's built in lens (f=4mm), enabling measurements of long capillaries (125 mm) to be made from a distance of 160 mm. The number of parallel measurements which can be made is determined by the size of the secondary lens. Based on these results, a more compact configuration with shorter 32 mm capillaries and a plano-convex lens with a shorter focal length (f=10mm) was constructed. This optical system was used to measure serial dilutions of fluorescein with a limit of detection (LOD) of 10nM, similar to the LOD of a commercial plate reader. However, many plate readers based on standard 96 well plate requires sample volumes of 100 μl for measurement, while the capillary array requires a sample volume of less than 10 μl. This optical configuration allows for a device to make use of the â¼100 à increase in fluorescent detection sensitivity produced by capillary amplification while maintaining a compact size and capability to analyze extremely small sample volumes. Such a device based on a phone or other optical mHealth technology will have the sensitivity of a conventional plate reader but have greater mHealth clinical utility, especially for telemedicine and for resource-poor settings and global health applications.
Orthographic projection capillary array fluorescent sensor for mHealth.
用于移动医疗的正交投影毛细管阵列荧光传感器
阅读:7
作者:Balsam Joshua, Bruck Hugh Alan, Rasooly Avraham
| 期刊: | Methods | 影响因子: | 4.300 |
| 时间: | 2013 | 起止号: | 2013 Oct;63(3):276-81 |
| doi: | 10.1016/j.ymeth.2013.07.044 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。