Anti-adherence capacity of phytosphingosine on titanium surfaces.

植物鞘氨醇对钛表面的抗粘附能力

阅读:6
作者:Liinoja Enni, Areid Nagat, Närvä Elisa, Bikker Floris J, Loimaranta Vuokko, Närhi Timo O
Firm soft tissue attachment on oral implant components together with good bacterial control are important prerequisites for uneventful implant healing. TiO(2) coatings have been shown to enhance human gingival fibroblast attachment, but the coating does not have antimicrobial properties. Phytosphingosine (PHS) is known to have antifouling properties against the cariogenic bacterium Streptococcus mutans (S. mutans) which is also among the first colonizers on implant surfaces. This makes PHS an interesting agent to prevent microbial adhesion on dental implant surfaces. The aim of this study was to examine the impact of PHS on S. mutans and human gingival fibroblast adhesion on titanium surfaces with or without TiO(2) -coating. Titanium discs (n = 99, diameter 14 mm, thickness 1 mm) were fabricated for the study. The discs were divided into four groups: (1) non-coated discs (NC), (2) titanium discs with hydrothermally induced TiO(2) coatings (HT), (3) NC discs treated with PHS solution and (4) HT discs treated with PHS solution. Hydrophilicity of the discs was evaluated by water contact angle measurement. S. mutans was added on HT and NC discs with or without PHS treatment for 30 minutes and the number of attached bacteria was estimated by plate counting method. For fibroblast experiment, the cells were plated on the discs and the number of adhered fibroblasts was determined at three time points (1, 3, 6 h). Additionally, confocal microscope images were obtained to examine fibroblast and S. mutans adhesion and to evaluate cell spreading. PHS treatment significantly decreased the hydrophilicity of HT and NC titanium surfaces (p < .001). S. mutans adhesion was significantly reduced after PHS treatment on both NC (p < .001) and HT surfaces (p < .001). Fibroblast adhesion was significantly reduced in HT group at 1 and 3h time points (p < .001), situation leveling out by the 6th hour. PHS reduced the number of adhered fibroblasts to the surface at incubation times of 1 hours (p = .0011) and 3 hours (p = .0194). At the 6 hour time point the number of adhered cells was no longer reduced, but still a reduction in cell spreading on the surface was observed (p < .05). The adhesion differences were present only in HT group. The PHS treatment reduced adherence of S. mutans and fibroblasts on TiO(2) coated titanium, which may result from reduced hydrophilicity of the surfaces. The dual approach of PHS treatment and TiO(2) coating could provide microbial antifouling properties of dental implants but may also affect fibroblast adhesion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。