Is it Possible to Obtain Immunofluorescence Data in Formalin-Fixed Paraffin-Embedded Skin Samples for the Diagnosis of Pemphigus Vulgaris and Bullous Pemphigoid.

能否从福尔马林固定石蜡包埋的皮肤样本中获得免疫荧光数据,用于寻常型天疱疮和大疱性类天疱疮的诊断?

阅读:5
作者:Ates Ozdemir Deniz, Gokoz Ozay, Saglam Arzu
OBJECTIVE: The gold-standard method for assessment of autoimmune bullous disease is direct/indirect immunofluorescence (IF) examination applied to fresh frozen tissue. Since the sensitivity of IF is greatly reduced in formalin-fixed paraffin-embedded (FFPE) tissues, IF cannot be relied upon in these samples. However, immunohistochemistry with the C4d antibody is a promising marker used as a surrogate for immune complex deposition, in nephropathology practice, and the paraffin IF method is also used as a `salvage` technique when fresh frozen tissue is not available or lacks glomeruli. We aimed to investigate whether it is possible to obtain immunofluorescence data from FFPE tissues diagnosed with bullous pemphigoid (BP) and pemphigus vulgaris (PV) and its relationship with inflammatory parameters in the skin. MATERIAL AND METHODS: Eighty-nine in-house cases with both IgG and C3 positivity by routine immunofluorescence examination were included in the study. Inflammation parameters were evaluated in hematoxylin-eosin sections. Immunofluorescence study with IgG protease digestion and C4d immunohistochemistry were performed. RESULTS: Results of 83 biopsies were obtained by paraffin immunofluorescence with IgG. There were positive reactions in 28 (34%) of these 83 biopsies. Five of the 28 positive results belonged to BP (18%), and 23 were PV (82%). Ten positive results were on lesional skin (36%), and 18 (64%) were on non-lesional skin. In the immunohistochemical study with C4d, 84 biopsy results were obtained. There were positive reactions in 34 (40.4%) of 84 biopsies. Of the 34 positive results, 12 belonged to BP (35.3%) and 22 to PV (64.7%). Again, 22 (64.7%) of 34 positive results belonged to lesional skin, and 12 (35.3%) belonged to non-lesional skin. When both techniques were used together, 44 (54%) of 81 biopsies yielded positive results for at least one of the two studies, while in 37 (46%), both tests showed negative results. CONCLUSION: The sensitivity of both IgG and C4d was less than in the literature, especially in BP-diagnosed biopsies. Positive samples were mostly PV. In conclusion, obtaining immunofluorescence data in FFPE samples is possible and is independent of the related skin being lesional or not, however, negative results should not be relied upon.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。