RATIONALE AND OBJECTIVES: The aim of this study was to optimize and validate projection-space denoising (PSDN) strategies for application to 80-kV computed tomographic (CT) data to achieve 50% dose reduction. MATERIALS AND METHODS: Image data obtained at 80 kV (mean CT dose index volume, 7.9 mGy) from dual-source, dual-energy CT enterographic (CTE) exams in 42 patients were used. For each exam, nine 80 kV image data sets were reconstructed using PSDN (three levels of intensity) with or without image-based denoising and compared to commercial reconstruction kernels. For optimization, qualitative analysis selected optimal denoising strategies, with quantitative analysis measuring image contrast, noise, and sharpness (full width at half maximum bowel wall thickness, maximum CT number gradient). For validation, two radiologists examined image quality, comparing low-dose 80-kV optimally denoised images to full-dose mixed-voltage images. RESULTS: PSDN algorithms generated the best 80-kV image quality (41 of 42 patients), while the commercial kernels produced the worst (39 of 42) (P < .001). Overall, 80-kV PSDN approaches resulted in higher contrast (mean, 332 vs 290 Hounsfield units), slightly less noise (mean, 20 vs 26 Hounsfield units), but slightly decreased image sharpness (relative bowel wall thickness, 1.069 vs 1.000) compared to full-dose mixed-voltage images. Mean image quality scores for full-dose CTE images were 4.9 compared to 4.5 for optimally denoised half-dose 80-kV CTE images and 3.1 for nondenoised 80-kV CTE images (P < .001). CONCLUSION: Optimized denoising strategies improve the quality of 80-kV CTE images such that CT data obtained at 50% of routine dose levels approaches the image quality of full-dose exams.
Feasibility of dose reduction using novel denoising techniques for low kV (80 kV) CT enterography: optimization and validation.
利用新型去噪技术降低低 kV (80 kV) CT 小肠造影剂量的可行性:优化和验证
阅读:6
作者:Guimarães LuÃs S, Fletcher Joel G, Yu Lifeng, Huprich James E, Fidler Jeff L, Manduca Armando, Ramirez-Giraldo Juan Carlos, Holmes David R Jr, McCollough Cynthia H
| 期刊: | Academic Radiology | 影响因子: | 3.900 |
| 时间: | 2010 | 起止号: | 2010 Oct;17(10):1203-10 |
| doi: | 10.1016/j.acra.2010.07.001 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
