Abstract

The Ames assay is the standard assay for identifying DNA-reactive genotoxic substances. Multiple formats are available and the correct choice of an assay protocol is essential for achieving optimal performance, including fit for purpose detection limits and required screening capacity. In the present study, a comparison of those parameters between two commonly used formats, the standard pre-incubation Ames test and the liquid-based Ames MPF™, was performed. For that purpose, twenty-one substances with various modes of action were chosen and tested for their lowest effect concentrations (LEC) with both tests. In addition, two sources of rat liver homogenate S9 fraction, Aroclor 1254-induced and phenobarbital/β-naphthoflavone induced, were compared in the Ames MPF™. Overall, the standard pre-incubation Ames and the Ames MPF™ assay showed high concordance (>90%) for mutagenic vs. non-mutagenic compound classification. The LEC values of the Ames MPF™ format were lower for 17 of the 21 of the selected test substances. The S9 source had no impact on the test results. This leads to the conclusion that the liquid-based Ames MPF™ assay format provides screening advantages when low concentrations are relevant, such as in the testing of complex mixtures.