A paradigm shift is occurring in clinical oncology exploiting the recent discovery that short pulses of ultra-high dose rate (UHDR) radiation-FLASH radiotherapy-can significantly spare healthy tissues whilst still being at least as effective in curing cancer as radiotherapy at conventional dose rates. These properties promise reduced post-treatment complications, whilst improving patient access to proton beam radiotherapy and reducing costs. However, accurate dosimetry at UHDR is extremely complicated. This work presents measurements performed with a primary-standard proton calorimeter and derivation of the required correction factors needed to determine absolute dose for FLASH proton beam radiotherapy with an uncertainty of 0.9% (1[Formula: see text]), in line with that of conventional treatments. The establishment of a primary standard for FLASH proton radiotherapy improves accuracy and consistency of the dose delivered and is crucial for the safe implementation of clinical trials, and beyond, for this new treatment modality.
Absolute dosimetry for FLASH proton pencil beam scanning radiotherapy.
FLASH质子笔形束扫描放射治疗的绝对剂量测定
阅读:6
作者:Lourenço Ana, Subiel Anna, Lee Nigel, Flynn Sam, Cotterill John, Shipley David, Romano Francesco, Speth Joe, Lee Eunsin, Zhang Yongbin, Xiao Zhiyan, Mascia Anthony, Amos Richard A, Palmans Hugo, Thomas Russell
| 期刊: | Scientific Reports | 影响因子: | 3.900 |
| 时间: | 2023 | 起止号: | 2023 Feb 4; 13(1):2054 |
| doi: | 10.1038/s41598-023-28192-0 | ||