Variability and reproducibility of multi-echo T(2) relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions.

多回波 T(2) 弛豫测量的变异性和可重复性:来自多中心、多会话和多受试者 MRI 采集的见解

阅读:5
作者:Fischi-Gomez Elda, Girard Gabriel, Koch Philipp J, Yu Thomas, Pizzolato Marco, Brügger Julia, Piredda Gian Franco, Hilbert Tom, Cadic-Melchior Andéol G, Beanato Elena, Park Chang-Hyun, Morishita Takuya, Wessel Maximilian J, Schiavi Simona, Daducci Alessandro, Kober Tobias, Canales-Rodríguez Erick J, Hummel Friedhelm C, Thiran Jean-Philippe
Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T(2) relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T(2) relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space (T2IE) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T(2) relaxometry dataset. To this end, we evaluated three different techniques for estimating the T(2) spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that T2IE is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。