Exposure to endocrine-disrupting compounds (EDCs) can alter steroid hormone production in vertebrates, sometimes leading to adverse reproductive or developmental effects. Liquid chromatography mass spectrometry methods are the gold standard for analyte confirmation and quantification in biological matrices, but radioimmunoassays (RIAs) are most commonly used for measurement of select steroid hormones in aquatic toxicology studies. Existing methods for steroid quantification often employ derivatization, limiting the range of steroids that can be simultaneously measured in a single process. In the current study, a method for the simultaneous measurement of thirteen endogenous steroids in small sample volumes without derivatization using liquid chromatography atmospheric pressure photoionization tandem mass spectrometry (LC-APPI-MS/MS) was developed. Several physiologically important steroids, including 11-deoxycortisol, 11-ketotestosterone, 17α- and 17β-estradiol, 17α-hydroxyprogesterone, 17,20β-dihydroxyprogesterone, 17,20β,21-trihydroxyprogesterone, androstenedione, cortisol, estriol, estrone, progesterone, and testosterone, were selected for the analysis. The method was validated for application to small volumes of fish plasma and fish holding water. Method detection limits using only 10 µL of plasma ranged from 0.05 to 1.0 ng/mL. As a potential surrogate for plasma steroid measurements, fish holding water was analyzed to measure excreted steroids. Lower limits of quantification when using 0.25 L of water ranged from 0.05 to 1.0 ng/L. The validated method was applied to two different experiments with small fish species exposed to an EDC known to affect steroid synthesis, fadrozole. Concentrations of the 13 steroids were measured in plasma or holding water from the studies. This work demonstrates the potential application of the developed method to measure endogenous steroids for identification of EDCs in aquatic toxicology studies.
Simultaneous determination of a suite of endogenous steroids by LC-APPI-MS: Application to the identification of endocrine disruptors in aquatic toxicology.
利用 LC-APPI-MS 同时测定一系列内源性类固醇:在水生毒理学中鉴定内分泌干扰物的应用
阅读:6
作者:Blackwell Brett R, Ankley Gerald T
| 期刊: | Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences | 影响因子: | 2.800 |
| 时间: | 2021 | 起止号: | 2021 Jan 15; 1163:122513 |
| doi: | 10.1016/j.jchromb.2020.122513 | 研究方向: | 免疫/内分泌 |
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。