MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.
MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.
阅读:4
作者:Horowitz Gary L, Zaman Zahur, Blanckaert Norbert J C, Chan Daniel W, Dubois Jeffrey A, Golaz Olivier, Mensi Noury, Keller Franz, Stolz Herbert, Klingler Karl, Marocchi Alessandro, Prencipe Lorenzo, McLawhon Ronald W, Nilsen Olaug L, Oellerich Michael, Luthe Hilmar, Orsonneau Jean-Luc, Richeux Gérard, Recio Fernando, Roldan Esther, Rymo Lars, Wicktorsson Anne-Charlotte, Welch Shirley L, Wieland Heinrich, Grawitz Andrea Busse, Mitsumaki Hiroshi, McGovern Margaret, Ng Katherine, Stockmann Wolfgang
| 期刊: | Journal of Automated Methods & Management in Chemistry | 影响因子: | 0.000 |
| 时间: | 2005 | 起止号: | 2005;2005(1):8-25 |
| doi: | 10.1155/JAMMC.2005.8 | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。